• BGS Hosted Metadata
  •   Search
  •   Map
  •  Sign in

Continuous measurements of conductivity, dissolved oxygen, pH, temperature and water level in rivers (2002-2007) [LOCAR]

Continuous measurements of conductivity, dissolved oxygen, pH, temperature and water level from the Frome Piddle; Pang Lambourn and Tern catchments, recorded between 2002 and 2007. YSI sondes were installed at 16 sites in these catchments to record continuous measurements of conductivity, dissolved oxygen, pH and temperature. Druck pressure transducers were installed at the same sites to measure continuous water level values. The instruments were installed as part of the NERC funded Lowland Catchment Research (LOCAR) Programme to provide comparable baseline river water chemistry data across the LOCAR catchments. Data were collected continuously at 15-minutes intervals for periods of variable length, depending on site. Full details about this dataset can be found at https://doi.org/10.5285/00895096-e083-498f-9a52-b7f9e3291125

Simple

Date (Publication)
2015-11-05
Citation identifier
CEH:EIDC: / 1426780471009
Citation identifier
https://catalogue.ceh.ac.uk/id/00895096-e083-498f-9a52-b7f9e3291125
Citation identifier
doi: / 10.5285/00895096-e083-498f-9a52-b7f9e3291125
Other citation details

Leach, D., Henville, P., Wyatt, R., Hewitt, E., Morrissey, I., Weller, J., Tindall, C.I., Bachiller-Jareno, N. (2015). Continuous measurements of conductivity, dissolved oxygen, pH, temperature and water level in rivers (2002-2007) [LOCAR]. NERC Environmental Information Data Centre 10.5285/00895096-e083-498f-9a52-b7f9e3291125

Point of contact
Organisation name Individual name Electronic mail address Role
UK Centre for Ecology & Hydrology

Fry, M.

enquiries@ceh.ac.uk

Point of contact
Centre for Ecology & Hydrology

Leach, D.

enquiries@ceh.ac.uk

Author
Centre for Ecology & Hydrology

Henville, P.

enquiries@ceh.ac.uk

Author
Centre for Ecology & Hydrology

Wyatt, R.

enquiries@ceh.ac.uk

Author
Centre for Ecology & Hydrology

Hewitt, E.

enquiries@ceh.ac.uk

Author
University of Birmingham

Morrissey, I.

enquiries@ceh.ac.uk

Author
University of Birmingham

Weller, J.

enquiries@ceh.ac.uk

Author
Centre for Ecology & Hydrology

Tindall, C.I.

enquiries@ceh.ac.uk

Author
Centre for Ecology & Hydrology

Bachiller-Jareno, N.

enquiries@ceh.ac.uk

Author
NERC Environmental Information Data Centre

info@eidc.ac.uk

Publisher
NERC EDS Environmental Information Data Centre

info@eidc.ac.uk

Custodian
UK Centre for Ecology & Hydrology

enquiries@ceh.ac.uk

Owner
Maintenance and update frequency
Not planned
Maintenance note

Dataset completed

GEMET - INSPIRE themes, version 1.0

  • Environmental Monitoring Facilities

Access constraints
Other restrictions
Other constraints
no limitations
Use constraints
Other restrictions
Other constraints
This resource is made available under the terms of the Open Government Licence
Use constraints
Other restrictions
Other constraints

© UK Centre for Ecology & Hydrology

Use constraints
Other restrictions
Other constraints

If you reuse this data, you should cite: Leach, D., Henville, P., Wyatt, R., Hewitt, E., Morrissey, I., Weller, J., Tindall, C.I., Bachiller-Jareno, N. (2015). Continuous measurements of conductivity, dissolved oxygen, pH, temperature and water level in rivers (2002-2007) [LOCAR]. NERC Environmental Information Data Centre https://doi.org/10.5285/00895096-e083-498f-9a52-b7f9e3291125

Spatial representation type
Text, table
Language
English
Character set
UTF8
Topic category
  • Environment
Begin date
2002-08-30
End date
2007-04-12
N
S
E
W
thumbnail




Unique resource identifier
OSGB 1936 / British National Grid
Distribution format
Name Version

Comma-separated values (CSV)

Distributor contact
Organisation name Individual name Electronic mail address Role

NERC EDS Environmental Information Data Centre

enquiries@ceh.ac.uk

Distributor
OnLine resource
Protocol Linkage Name
https://data-package.ceh.ac.uk/data/00895096-e083-498f-9a52-b7f9e3291125

Download the data

OnLine resource
Protocol Linkage Name
https://data-package.ceh.ac.uk/sd/00895096-e083-498f-9a52-b7f9e3291125.zip

Supporting information

Hierarchy level
Dataset
Other

dataset

Conformance result

Title

Commission Regulation (EU) No 1089/2010 of 23 November 2010 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards interoperability of spatial data sets and services

Date (Publication)
2010-12-08
Statement

Temperature, pH, conductivity and dissolved oxygen data were collected using YSI 6-Series multi-parameter water quality sondes. Each sonde had multiple sensors that read water quality data. Water level data were collected using Druck Pressure Transducers. The transducers were fully submersible high performance sensors that produced reliable and accurate water level measurements. After two weeks of deployment in the river the sondes were taken back to the laboratory for calibration checks, cleaning, changing the membrane on the oxygen electrode and recalibration. During their transportation and storage they were kept moist at all times by adding a few drops of deionised water in the containing bottle. On return to the laboratory, the outside of the sonde body was wiped to remove silt, etc. The electrode guard was removed and the body of the electrode rinsed, avoiding cleaning the surface of the electrodes. The sonde was then connected to the battery pack and computer and the calibration software launched. Then, in the corresponding calibration software menus, the specific conductance, conductivity, dissolved oxygen charge were activated and their post calibration values recorded in the post calibration form. Before the sondes could be returned to the field they needed to be recalibrated. First, the glass surface of the pH electrode was gently wiped with a cotton bud wetted in alcohol. The inside of the conductivity electrode was scrubbed with a small bottle brush then the sonde was rinsed with distilled water. The 'O' ring was removed and the plastic membrane from the oxygen electrode was replaced by a new one. The 'O' ring was then replaced. The new membrane needed at least 12 hours to condition before calibration. The sonde was therefore left in the transportation pot (containing moist sponge) until the next day before being calibrated. To calibrate the sonde, it was connected to the battery pack and the computer. From the calibration routine, in the sonde software menu, the dissolved oxygen charge was activated. Then dissolved oxygen, conductivity and pH were consecutively selected for calibration. The Catchment Service Team in each catchment was responsible for installing, maintaining and downloading the loggers on the YSI sondes and Druck pressure transducers at each site on a regular basis. Data are raw and have not been quality controlled nor corrected for instrument failure or instrument drift. A zip file containing box-and-whisker plots for each determinand, showing the range of values (median, inter-quartile range, 1.5 * inter-quartile range, outliers) recorded at each site is available to enable prospective users of the data to understand data quality. (For further details see the supporting documentation for this dataset)

Metadata

File identifier
00895096-e083-498f-9a52-b7f9e3291125 XML
Metadata language
English
Character set
8859 Part 1
Hierarchy level
Dataset
Hierarchy level name

dataset

Date stamp
2025-03-21T10:49:57
Metadata standard name
UK GEMINI
Metadata standard version

2.3

Metadata author
Organisation name Individual name Electronic mail address Role
NERC EDS Environmental Information Data Centre

info@eidc.ac.uk

Point of contact
 
 

Overviews

Spatial extent

thumbnail

Keywords

GEMET - INSPIRE themes, version 1.0

Environmental Monitoring Facilities


Provided by

logo

Share on social sites

Access to the catalogue
Read here the full details and access to the data.




  •   About
  •   Github
  •