• BGS Hosted Metadata
  •   Search
  •   Map
  •  Sign in

Water temperature measurements from Durleigh Reservoir 2018

This dataset contains water temperature measurements at two different locations in Durleigh Reservoir in Somerset, England. Water temperatures were measured using RBR SoloT thermistors (measured in deg C) and HOBO TidbiT v2 loggers (measured in deg F). The dataset consists of water temperature measurements from two locations at Durleigh reservoir between 22 February 2018 and 5 October 2018. Measurements were taken at 10 minute intervals. Full details about this dataset can be found at https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731

Simple

Date (Publication)
2020-05-05
Citation identifier
https://catalogue.ceh.ac.uk/id/25d34c83-e939-40fd-aa16-6962efb4c731
Citation identifier
doi: / 10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
Other citation details

Slavin, E.I., Wain, D.J. (2020). Water temperature measurements from Durleigh Reservoir 2018. NERC Environmental Information Data Centre 10.5285/25d34c83-e939-40fd-aa16-6962efb4c731

Point of contact
Organisation name Individual name Electronic mail address Role

University of Bath

Slavin, E.I.

eis24@bath.ac.uk

Author

7 Lakes Alliance

Wain, D.J.

djwain@colby.edu

Author

University of Bath

Slavin, E.

eis24@bath.ac.uk

Point of contact
NERC EDS Environmental Information Data Centre

info@eidc.ac.uk

Custodian
NERC Environmental Information Data Centre

info@eidc.ac.uk

Publisher

GEMET - INSPIRE themes, version 1.0

  • Environmental Monitoring Facilities

GEMET - Concepts, version 4.1.3

  • reservoir
Keywords
  • Water quality
  • Pollution
  • Environmental survey
Access constraints
Other restrictions
Other constraints
no limitations
Use constraints
Other restrictions
Other constraints

© University of Bath

Use constraints
Other restrictions
Other constraints
This resource is available under the terms of the Open Government Licence
Use constraints
Other restrictions
Other constraints

If you reuse this data, you should cite: Slavin, E.I., Wain, D.J. (2020). Water temperature measurements from Durleigh Reservoir 2018. NERC Environmental Information Data Centre https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731

Spatial representation type
Text, table
Distance
50  urn:ogc:def:uom:EPSG::9001
Language
English
Character set
UTF8
Topic category
  • Inland waters
  • Environment
Begin date
2018-02-22
End date
2018-10-05
N
S
E
W
thumbnail




Unique resource identifier
OSGB 1936 / British National Grid
Distribution format
Name Version

Comma-separated values (CSV)

Distributor contact
Organisation name Individual name Electronic mail address Role

NERC EDS Environmental Information Data Centre

info@eidc.ac.uk

Distributor
OnLine resource
Protocol Linkage Name
https://data-package.ceh.ac.uk/data/25d34c83-e939-40fd-aa16-6962efb4c731

Download the data

OnLine resource
Protocol Linkage Name
https://data-package.ceh.ac.uk/sd/25d34c83-e939-40fd-aa16-6962efb4c731.zip

Supporting information

Hierarchy level
Dataset
Other

dataset

Conformance result

Title

Commission Regulation (EU) No 1089/2010 of 23 November 2010 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards interoperability of spatial data sets and services

Date (Publication)
2010-12-08
Statement

The first site, labelled location 2, is closer to the artificial mixing devices (surface mixers) installed in the reservoir (60 m away) and deeper, with a water depth of 6 m when on deployment (latitude: 51.1210, longitude: -3.0403). The second site, labelled location 3, is farther away from the artificial mixing devices installed in the reservoir (435 m away) and in a shallower region, with a water depth of 4 m on deployment (latitude: 51.1215, longitude: -3.0445). At location 2, RBR SoloT thermistors (measured in deg C) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (6 m). However, in the dataset temperature measurements from thermistors positioned at 1 m, 2 m, and 3 m are missing due to corrupted files. At location 3, HOBO TidbiT v2 loggers (measured in deg F) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (4 m depth). All water temperature measurements were taken at 10-minute intervals. Both temperature chains consisted of a buoy (A2 size) attached to a 10 kg weight using a rope, and the thermistors were attached onto the rope. All thermistors were deployed between 22 February and 5 October 2018.

Metadata

File identifier
25d34c83-e939-40fd-aa16-6962efb4c731 XML
Metadata language
English
Character set
8859 Part 1
Hierarchy level
Dataset
Hierarchy level name

dataset

Date stamp
2025-11-13T16:24:09
Metadata standard name
UK GEMINI
Metadata standard version

2.3

Metadata author
Organisation name Individual name Electronic mail address Role
NERC EDS Environmental Information Data Centre

info@eidc.ac.uk

Point of contact
 
 

Overviews

Spatial extent

thumbnail

Keywords

GEMET - INSPIRE themes, version 1.0

Environmental Monitoring Facilities


Provided by

logo

Share on social sites

Access to the catalogue
Read here the full details and access to the data.




  •   About
  •   Github
  •